Newsroom
203
Cat.No.:
  • MVN400-05
  • MVN400-06

MagCore® Viral Nucleic Acid Extraction Kit High Sensitivity

For extraction of viral DNA/RNA from serum plasma saliva and cell-free body fluids

MagCore® Viral Nucleic Acid Kits are designed to isolate viral DNA and/or RNA from plasma, serum, swabs, and cell-free body fluids. All plastic consumables included in the kits are DNase/RNase-free to minimize the risk of cross-contamination. Our patented magnetic beads will bind to the short DNA fragments with high affinity ensuring that all important genetic information is collected efficiently making your daily isolation routine easier and faster. This kit also features Internal Control selection in its protocol, being compatible with any viral detection kit.

MagCore® Viral Nucleic Acid Extraction Kit High Sensitivity

Feature

Higher analytical sensitivity.

Consistent and reproducible results.

High performance of purified DNA/RNA in downstream applications such as qPCR.

Cartridges are pre-filled and sealed to prevent contamination.

Provides the option of Internal Control selection.

Applications

MagCore® Viral Nucleic Acid Extraction Kit is designed to allow automated processing of multiple sample types in the same run.
Sample types include:

  1. Cell-Free Body Fluids
  2. Plasma and Serum
  3. CSF
  4. Urine
  5. Swabs

Performance

Viral Nucleic Acid Extraction Performance Analysis

MagCore®203 shows better performance on real-time PCR with approximately 1~2 Ct Value less. (n≥3)
 

Comparison of real-time PCR results of nucleic acid extraction
by MagCore®, Brand Q and Brand R


Purified viral nucleic acid by MagCore® is ideal for the downstream real-time PCR. Viral samples processed by MagCore®

Internal Control (IC) Selection

 No.  Kit  Signal  Sample   Concentration (IU/mL)
HBV Signal / IC Signal
 NTC 
5x106 5x105 5x104 5x103 -/-
1 MagCore® 203 HBV 22.06 25.39 28.58 30.53
+IC 29.99 31.54 31.17 31.55
2 HBV 23.82 26.51 29.78 33.17
+IC 31.19 30.79 30.51 32.73

MagCore®203 program provides internal control (IC) selection, and the real-time PCR analyzed by the CE IVD HBV Quantification kit shows IC signal within criteria (Ct value 30±3). This confirms success in the MagCore®203 viral extraction step and low co-purification of PCR inhibitors that may cause false amplification patterns.

Specification

Cartridge Contents

Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • Cartridge Contents
  • 1

    Heat block Well 1

  • 2

    Heat block Well 2

  • 3

    Wash 2 Buffer 1000µl

  • 4

    Wash 2 Buffer 1000µl

  • 5

    RNase Free Water 1000µl

  • 6

    RNase Free Water 1000µl

  • 7

    Wash 1 Buffer 1000µl

  • 8

    Wash 1 Buffer 1000μl

  • 9

    Beads Mixture 500μl

  • 10

    Binding Buffer 1000µl

  • 11

    Lysis Buffer 1000µl

  • 12

    Empty

  • 13

    Magnetic Beads Separation Well 1

  • 14

    Magnetic Beads Separation Well 2

Cat.No. : MVN400-05

introduction

Storage And Stability : Store at Room Temperature

Packing : 36 tests / Kit

Contents

Pre-Filled Cartridge Reagent ( 36 pcs )

Pipette Tip and Holder Set ( 36 sets )

Sample Tube ( 36 pcs )

Elution Tube ( 36 pcs )

Carrier RNA ( 1 mg/pcs x 1 pcs )

RNase Free Water ( 1.25 ml/tube x 1 pcs )

Proteinase K ( 11 mg/tube x 1 pcs )

PK Storage Buffer ( 1.25 ml/tube x 1 pcs )

Cat.No. : MVN400-05

Cat.No. : MVN400-06

introduction

Storage And Stability : Store at Room Temperature

Packing : 96 tests / Kit

Contents

Pre-Filled Cartridge Reagent ( 96 pcs )

Pipette Tip and Holder Set ( 96 sets )

Sample Tube ( 96 pcs )

Elution Tube ( 96 pcs )

Carrier RNA ( 1 mg/pcs x 1 pcs )

RNase Free Water ( 1.25 ml/tube x 1 pcs )

Proteinase K ( 11 mg/tube x 2 pcs )

PK Storage Buffer ( 1.25 ml/tube x 2 pcs )

Cat.No. : MVN400-06